Summary |
Description :
Capacity 1200VA. Voltage (on battery) Simulated sine wave at 100V / 220V / 240V +/- 8% --- AVE control with PWM. Frequency (on battery) 50 or 60Hz +/- 1Hz. Transfer Time 4 microseconds (Typical). Input Voltage (single phase + N) 100V / 110V +/-20%, 120V -20%, +15% 220V / 230V / 240V, 160V ~ 270V at line input. Overload Protection UPS automatic shutdown if overload exceeds110% at 10 seconds, 130% at 3 seconds. Short Circuit UPS output cut off immediately. Spike Protection.460 Joules, (8/20?s). Battery Type Sealed, maintenance-free lead acid batteries. Typical Recharge Time (to 90% of full capacity) 6 Hours. Back-up Time ( PC with 15?? monitor) Full Load 30 minutes,Half Load 40 minutes. Protection Automatic self-test, Over discharge protection, short circuit protection by fuse. Net Weight 8.7 kg. AC Normal Indicator GREEN. Battery Charging AMBER. Back Up Indicator RED. Ambient Operation 3,500 meters max. elevation, 0-95% humidity (No-condensing water), 0-40 deg Audible Noise < 40dBA (1 meter from surface)
Features:
Capacity: 1200VA
Voltage (on battery): Simulated sine wave at 100V / 220V / 240V +/- 8% --- AVE control with PWM
Frequency (on battery): 50 or 60Hz +/- 1Hz
Transfer Time: 4 microseconds (Typical)
Input Voltage (single phase + N): 100V / 110V +/-20%, 120V -20%, +15% 220V / 230V / 240V, 160V ~ 270V at line input
Overload Protection: UPS automatic shutdown if overload exceeds110% at 10 seconds, 130% at 3 seconds
Short Circuit: UPS output cut off immediately
Spike Protection: 460 Joules, (8/20?s)
Battery Type: Sealed, maintenance-free lead acid batterie (1pc=8Amp)
Typical Recharge Time (to 90% of full capacity): 6 Hours
Back-up Time Full Load 30 minutes,Half Load 40 minutes
Protection: Automatic self-test, Over discharge protection, short circuit protection by fuse
Net Weight kg: 8.7 kg
AC Normal Indicator: GREEN
Battery Charging: AMBER
Back Up Indicator: RED
Ambient Operation: 3,500 meters max. elevation, 0-95% humidity (No-condensing water), 0-40 deg
Audible Noise: < 40dBA (1 meter from surface)
.. |
.. |
MaxGreen 850VA Offline UPS
MaxGreen 850VA Offline UPS Capacity 850VA/480W. Input Voltage 220Vac. Input Voltage Range 140-290VAC. Frequency Range 50 Hz. Output Voltage 220Vac. AC Voltage Regulation ±10% (Bat Mode). Frequency Range 50Hz ± 1Hz (Bat Mode). Transfer time Typical 2-6ms. Waveform Simulated Sine Wave (Bat Mode). Battery Internal maintenance-free lead-acid. Battery Type & Number 12V/9Ah*1. Net Weight (kg) 4.2 4.6. Dimension,D*W*H(mm) 297X101X142. Typical Recharge Time 4-6 hours recover to 90% capacity. Full protection Short circuit, Overload, Battery discharge and overcharge, Surge protection. Humidity 0-90% Relative Humidity 0-40 ℃ (Non-condensing). Noise Level Less than 40dB. Optional USB/RS232 Port Supports Windows 2000/2003/XP/Vista/2008,Windows 7/8 Linux Unix and MAC... |
MaxGreen MG-LI-EAP 1200VA Offline UPS
MaxGreen MG-LI-EAP 1200VA Offline UPS comes with a capacity of 1200VA that provides emergency power backup with the help of batteries when the input power source fails. This uninterruptible power supply unit has Nominal Voltage 220v, Voltage regulation 1%, Frequency range - Hz: 50±1%, Transfer time 2 to 6 ms, AC voltage regulation ±10%, and Simulated sine wave, which is enough to start a standby power source or shut down necessary equipment for saving from the damage. The Offline UPS comes with Voltage 220/230V, Voltage range 140-290, Frequency range 50HZ. This device contains a maintenance fee lead-acid battery (Number of batteries 2 ) which has 12V 7 Ah Battery Capacity, that provides surge protection and power backup while incoming voltage falls, It also provides 15-30 Depends on load Backup Time. This internal storage battery ensures the power that goes below or rises above a certain level through an internal DC-AC inverter. The Offline UPS also featured with an Operating temperature of 0 to 40 deg. centigradeStorage temperature -15 to 50 deg. centigrade Noise level .. |